Molecular Formula | C8H16O3 |
Molar Mass | 160.21 |
Density | 1.0227 (rough estimate) |
Boling Point | 226.12°C (rough estimate) |
Flash Point | 43 °C |
Water Solubility | 3.96g/L at 20℃ |
Vapor Presure | 5.04hPa at 37℃ |
Appearance | ester-like colourless liquid |
Stability | Not explosive |
Refractive Index | 1.4370 (estimate) |
Physical and Chemical Properties | The substance or mixture is not classified as oxidizing. |
Use | Delivery Form:50% solution in aliphatics |
UN IDs | UN 2142/2562 |
Hazard Class | 5.2 |
Packing Group | II |
Acute toxicity
Acute oral toxicity: LD50 (rat):>5000 mg/kg
Methods: OECD test guidelines 401
Evaluation: The substance or mixture has no acute oral toxicity
Remarks: Data based on similar materials
Acute inhalation toxicity: Remarks: No data
Acute skin toxicity: LD50 skin (rabbit):>5000 mg/kg
Methods: OECD test guidelines 402
Skin corrosion/irritation
Results: Repeated contact may cause dry skin or cracking.
Severe eye injury/eye irritation
Results: No eye irritation
Mutagenicity of germ cells
Mutagenicity of germ cells. Evaluation
carcinogenicity
Hydrogenation:
Carcinogenicity-assessment
: There is no known effect.
Reproductive toxicity
Hydrogenation:
Reproductive toxicity-assessment
: There is no known effect.
Inhalation toxicity
Hydrogenation:
It can be fatal if swallowed and into the respiratory tract.
Further information
Products:
Note: The solvent may degrease the skin.
Hydrogenation:
Remarks: It may cause headache and dizziness.
10.1 reactivity
Stable under recommended storage conditions.
10.2 chemical stability
Stable under recommended storage conditions.
Possibility of 10.3 dangerous reactions
Hazardous reaction: Steam may form an explosive mixture with air.
Conditions to be avoided by 10.4
Conditions to avoid: prevent pollution.
Contact with incompatible substances can lead to decomposition at or below SADT.
Heat, flames and sparks.
Avoid imprisonment.
10.5 incompatible materials
Avoid materials: accelerators, strong acids and bases, heavy metals and
Heavy metal salts, reducing agents
10.6 harmful decomposition products
There are no known harmful decomposition products.
storage requirements
Areas and containers: avoid impurities (such as rust, dust, ashes) to avoid decomposition.
Electrical installations/working materials must meet technical safety standards. After the container is opened, it must be carefully resealed and kept upright to prevent leakage from being stored in the original container. Keep the container tight
In a well-ventilated place. In accordance with specific national regulations.
General storage recommendations: stay away from strong acids, strong alkalis, heavy metal salts and other harmful substances
Other reducing substances.
Recommended storage temperature:<10°C
More information about storage stability: If stored normally, it will not be decomposed.
LogP | 2.68 at 25℃ |
EPA chemical information | Information provided by: ofmpub.epa.gov (external link) |
category | oxidant |
explosive hazard characteristics | explosive decomposition when heated; concentrated solution is explosive |
flammability hazard characteristics | flammable; Flammable when mixed with reducing agent, ammonium, organic matter, acid and flammable materials; Thermal decomposition discharges spicy and stimulating smoke |
storage and transportation characteristics | warehouse ventilation and low temperature drying; Store separately from organic matter, reducing matter, combustible matter and strong acid |
fire extinguishing agent | water, dry powder, carbon dioxide |